Calibrating the Nimble Sidewinder V2

Because of the gear ratio inside the Sidewinder V2, There are a lot more steps per millimeter than your usual number.

Note

Start with 1800 steps/mm with a 1.8deg stepper and 1/16 microstepping

The Sidewinder has a nice flat surface you can use to set the ruler on, when measuring the filament, simply place it on top of the “ears” of the breech block. Use a light coloured filament, place it in the breech, heat up the hot end and start the process.

  • Measure 100 mm on the filament, by holding the filament against the ruler while the ruler stands on the breech block ears.
  • Mark the distance with a permanent marker.
  • Extrude 50 mm using the firmware controls.
  • Measure the remaining length to the mark made.
  • Calculate the new number of steps/mm using the following formula:

Note

New steps = current steps * 50/actual mm extruded (50 being the 50 mm of filament you wanted to extrude.)

  • enter the new value in your firmware settings.
  • Do the whole sequence again, to confirm that the steps per millimeter are now set correctly.
  • if not, recalculate and re-confirm.

You have now set the extrusion rate of the Sidewinder correctly and have the nozzles set right. You can now start Using the Sidewinder.

See the Using the Sidewinder page or click Next.